熱水器加壓馬達壓馬達, 加壓泵, 加壓泵浦 ,,加壓器 , 馬達, 無聲, 無噪音, 靜音, 超靜音加壓馬達
 
泵浦, 加壓機, 穩壓馬達  熱水加壓泵浦, 熱水增壓器, 熱水加壓泵熱水加壓器, 加壓幫浦, 忽冷忽熱

Stainless Steel Water Heater Pump Circulator Pump With Water Flow Switch
Hot Water Booster Pump 110V60Hz

EagleFly Pump  110V AC 120W
The pump body is manufactured with stainless steel #304.
Hightough engineering plastic vanes, high water temperatures resistant,
Using magnetic floating axis that adapts to the
worldwide environment,
Build in
Water Flow Switch auto on/off when using hot water.
Head: 9 meters.

Purchase focus:
1. 3/4” NPT pump inlet and outlet design.
  Needs only #200 (8)and #250 (10) adjustable wrenches for installation.
2. AC 110V drive, high torque.
3. Power 120W
4. Heat lift 10 meters.
5. Waterproof IP44,
6. Flow rate of 30 liters per minute.
7. Quiet, start, pressurize, no sound, super silence, true DIY.
8. Stainless Steel #304 pump body no rust water.
9. Included install accessories (2 x 3/4” conver to 1/2” copper adapters,
+one 1/2”x1/2” coupling +1 x stainless steel corrugated flexible tube. )

15MX-9NS S.S. Water Heater Pump 110VAC 120W

15MX-9NS Eaglefly pump with stainless steel #304 pump body, no rust water, 
pure copper motor, DC enhanced horsepower 120W (Head 9 meters). 
Build in water flow sensor switch, magnetic floating water cooling shaft design,
AC booster, Brushless motor, automatic water cooling, centrifugal impeller,
super silent, ultra-quiet operation.

High temperature resistance can be used for water storage bucket or electric
water heaters and solar water heaters.


Old pipelines cannot withstand the pressure of the smallest
1/4Hp horsepower pressurized
motor sold in the market, the design of the
pressure-sensing switch requires constant pressure to be installed
in the rear section of the motor, which is liable to cause leaks in the old water pipe.


S.S. EagleFly hot water pump special designed for the old pipeline use 1
5MX-9NS 120W (1/6Hp horsepower)
small motor, small volume, large torque,
strong water flow providing enough water pressure for the water heater, economically,

Spend a small amount of money DIY, you can improve using quality of the hot water.

Bathing is no longer cold or too hot! 
This " hot water heater dedicated pump 15MX-9NS ", 
mini model, ultra-quiet magnetic motor technology, silence, power-saving, 
professional soft pressure on the hot water pipe
It can ensure that the water heater can be used for ignition and heating.
Suitable (gas / electricity) water heater, faucet pressurization, washing machine,
the bathroom faucet, shower head, toilet, solar hot water delivery booster.


No need to drill the wall design, suitable for self-installation, directly installed 
under the water heater, locked at the inlet end the wall cold water triangle valve.

Can effectively improve the water heater ignition is not smooth, hot water is 
too small and too hot, more suitable for holiday homes, cars, RVs, campers,
huts, home stays, ships... quietly in use, in line with the needs of the tranquil
environment,
let you use your peace of mind and wash comfortably!
The waterproof IP44.

Water Heater Pump Circulator Pump With Water Flow Switch NPT1/2''
Domestic Hot Water Booster Pump Shield Type 110V AC

Model15MX-9NS
Voltage
110V AC

Power
120W
Head
9 meters
Water pressure
1Kg/cm2
Power Supply
100V 60Hz power cord 1.2 meters
Pump Pipe diameter
3/4"
Maximum flow10 liters per minute

NoiseSuper silence <30dBA/10cm
Working temperature
+10C ~ +95C
Water proof
IP44
Weight2430g
Insulation classClass F
Pipe diameter
1/2" (15mm)
MotorAC brush less motor 
Product sizelength 7” x width 4” x height 5”

Two (2 ) Installation Method Cover Up All Application.

The whole set includes: S.S. pump + 2 sets of 3/4" to 1/2" movable S.S. connector + 1/2" double female S.S. connector + Packing filter + special 2 feet, 1/2" at one end and 3/4" at one end Large diameter 19mm stainless steel mesh hose

 
MEXA@AUTOPURE.COM


 

PUMP Before
After The water heater dedicated pump is installed in the cold water pipe as shown in the above example-after removing the original cold water hose, change it to 1/2" or 1/2" double female connector or 1/2" by any + 15MX-9NA pump + 1/2" at one end One end of the 3/4" inner teeth large diameter white iron mesh 2-foot hose is assembled with the flexible hose above. If the extension and flexion space is insufficient, the shape support ribs under the iron cover of the water heater can be cut to provide enough smooth rotation space as shown by the green arrow Refers to the part. If the pipeline still leaks from small slits after installation, you can wrap the white stop tape and repeat the disassembly again or consider fixing and reinforcing the stop leak with paint resin and caulking agent.

 

 
 
1. The pump bearing is water-lubricated, so do not run dry without water.
Do not plug in the power when the motor and water pipe are not filled with water.
The original factory cannot be returned or replaced due to human negligence.
2. Do not plug in the plug before installing this booster pump.
3. The "OUTLET" end of the pressure pump (outlet) water port has the black plastic control box up, and the lower end "INPUT" is the cold water inlet (in) end. And remember to remove the original sealing stickers on both ends when installing.
4. Before using after installation, remember to turn the control button to the "OFF" position, turn on the faucet at the water outlet, and discharge the air trapped in the pipeline after the device.
After 30 seconds, make sure that there is no air and the water is normal.
Only then can you plug in the power and turn the control button to "AUTO" to start using. (MANUAL) is to detect the position manually, usually not used.
The center bolt is a bleed valve. In order to remove the air accumulated in the pump body, usually when the pump is used for a period of time or there is abnormal water flow, turn off the power first and turn the bolt counterclockwise with 10 picks of coins, and slowly turn the bolt to the gas after draining and seeing the water flowing out, it can be locked in a clockwise direction immediately and used normally.
Remember to remove and replace the filters of all hot water outlets frequently.


1. In general, additional purchases are required: a) + b) [Refer to the following-important installation pipe fittings a) Step 1) Refer to the picture] a) 4 points double internal tooth vanity or 4 points double internal tooth copper adapter b) As shown in the installation diagram, a special 2 feet 4 points on one end and 6 points on one end Large diameter stainless steel mesh hose (this hose can also slightly solve the water hammer problem)

Step 1) Then, first turn the attached 3/4" to 1/2" (movable) copper adapter set's 1/2" head end screw Wrap the white leak stop tape, use a wrench and universal fixing pliers to lock it with item a), and then The other end of the copper adapter set a) is locked on the 1/2" thread of the triangle valve coming out of the wall (Remember that the screw must be wrapped with a white leak stop tape before locking).
Step 2) Put the hexagonal nut end of the (movable) copper adapter set into the black rubber ring gasket and lock it. Below the pump (Input), the water inlet end is on the 3/4" branch teeth (Because there is already Packing this thread, there is no need to wrap the white leak stop tape).
Step 3) Attach the 3/4" end of b) directly to the direction of the black control box above the pump (Outlet) The water outlet end 6 is in charge of the teeth (Because the thread is already embedded in Packing, there is no need to wrap the white leak stop tape).
Step 4) Thread the 1/2" head end of b) directly onto the 1/2" thread of the cold water inlet end of the tile water heater (Because the thread is already embedded in Packing, there is no need to wrap the white leak stop tape).


2. A hanging device can also be used at the cold water inlet of the water heater, First remove or disassemble the copper or stainless steel mesh hose on the far right of the pipeline under your water heater, Lock the bottom of the pipeline into the 3-angle valve on the wall, and turn it straight in the counterclockwise direction. (You can also remove the entire thread and re-wrap the white leak stop tape on the screw, and re-lock it.
Step 1) Then, first turn the attached 6-point to 4-point (movable) copper adapter set's 4-point head end screw Wrap the white anti-leak strap, use a wrench and universal fixing pliers to lock it with item a), and then The other end of the copper adapter set a) is locked on the 4-point screw thread of the cold water inlet of the gas water heater (Remember that the screw must be wrapped with a white stop tape before locking). If you order this part for this item (4 points) Double female copper adapter), our company will lock this component first.
Step 2) Put the 4 points (movable) of the hexagonal nut end of the copper adapter set that has been locked in step 1 into the black rubber Packing ring is properly locked on the 6-point screw thread of the water outlet end of the pump motor (Outlet) (Because there is already Packing, this 6-point screw does not need to be wrapped with a white leak stop tape).
Step 3) Attach the 6-point head hex nut of b) directly to the pump below the pump (Input) The cold water inlet end 6 is in charge of the teeth. (Because the thread is already embedded in Packing, there is no need to wrap the white leak stop tape).
Step 4) Attach the 4-point hex nut of b) directly to the cold water outlet on the wall. 4 points on the triangle valve teeth (because this thread is already embedded in Packing, there is no need to wrap the white leak stop tape).

The installation takes about 30 minutes, it can be removed and taken away.
The electric water heater can also be used,

The instant electric water heater or gas water heater is added to the cold water inlet end,
The hot water storage tank or solar water heater is added to the hot water outlet pipe end of the storage tank.
For other questions and answers, please refer to the following links:
http://www.autopure.com.tw/Pump1.htm
Installation key:

1. Do not plug in the power supply, install without electricity.

2. Please turn the switch adjustment button to the Auto position, and then install it.
3. After proper installation, first turn on all the hot water faucets supplied by this water heater,
After allowing the water to flow out for 20 seconds, plug in the power plug, and then let the hot water taps continue to flow After another 20 seconds, you can turn off the hot water faucets and use them normally. (You can use the old four-part general plastic water pipes, and clamp a 2-foot stainless steel large-diameter four-part large hose from the central split sleeve. Can solve the problem of resonance sound and water hammer)


Hot and cold water problem Users often complain that the hot water provided by the gas water heater is not hot, too hot or fluctuating hot and cold, Think that the water heater is faulty or the gas supply is insufficient. According to the repair results, it was found that almost none of them had anything to do with gas supply. Except for the dead battery in the water heater, most of the problems are caused by water pressure, which can be solved by installing a pressurizing motor. However, before installing a pressurizing motor, you may wish to check whether the various pipes and filters are blocked. Whether the hot and cold bellows are old and long and tortuous, whether the stainless steel-coated plastic hose of the shower head is small in diameter and too long, whether the adjustment switch of the water heater is correct, and the heat adjustment method of the water heater is controlled by two switches:

One is on the panel, which is to adjust the amount of gas and firepower Generally represented by the flame symbol, one represents small fire, two represents medium fire, and three represents large fire (all are step less control, That is to say, there is also a function between two paragraphs), and also expressed by color or arrow size, the thicker (darker) means the greater the fire, The thinner (shallower) means the smaller the fire. So first adjust the gas switch to test the water temperature you require, If the gas switch has been turned on to the maximum, it still cannot reach the water temperature you want, Then under the water heater, there is a left-right switch (red or white bar) which is a switch for adjusting the water volume.
Generally speaking, the water pressure in the building is higher and the water flow is faster, and the faster the speed, the lower the temperature of the water coming out.

So adjust the switch left and right to see, when the water volume becomes smaller or the flow rate becomes slower, the water temperature will increase.

If it can't be improved after adjustment, it can be solved by installing a pressurizing motor to increase the water pressure.


After installing the hot water pressurizing pump, finally adjust the water volume and firepower adjustment buttons on the electric or gas water heater.
Take a hot bath until it is most suitable for starting the pump and the most suitable comfortable water temperature.

1. Adjust the gas firepower adjustment knob on the water heater (the firepower can be adjusted) to adjust the water temperature to an appropriate temperature
(About 40~45 degrees). Please note that if the water temperature is too high, in addition to bulging the hot water pipes to bury the surrounding cement tiles, And it is easy to burn and waste gas.
2. Adjust the water volume regulating valve (red or white bar) or regulating button under the gas water heater to
The place where the amount of water is greatest (the direction of low temperature is the same). (Please adjust the water heater according to the instructions after installation) 1. Firepower adjustment knob from small to ---> large and 2. The water volume adjustment knob is from large to ---> small, until the position is suitable for your use.


This pump has a heat resistance of 100°C and can be installed in the hot water (outlet) pipe of an electric water heater or solar water heater to pressurize it.
Use a clean water source, the black automatic switch box is upwards during installation, and the installation position should avoid rain as much as possible. The attached small Packing filter gasket should be installed in front of the pump inlet. Simple troubleshooting: If the pump suddenly fails to operate after a period of use, the shaft may be jammed by impurities, resulting in There is no action in manual and Auto mode. First unplug the plug and turn off the water source after turning off the center drain with a $10 coin then use a flat-blade screwdriver to rotate the shaft a few times left and right, then lock the center bleed bolt, turn on the water source, plug in the plug, and turn the control button to "AUTO" to start using. Remember to remove and replace the filters of all hot water outlets frequently. The unique design of this pump is different from ordinary pressurizing motors: it will always last to keep the planned pressure within the pipe diameter after pressurization, It is easy to cause the old pipeline to burst and leak. After the pump is closed, the water pressure in the pipe diameter will immediately return to the water pressure when the pump is not installed. This protects the pipeline and reduces the pipeline load pressure.


Note: In order to avoid electrical induction events, this pump should be used with an additional power-off device.
WHY&ANSWER

    

Important device pipe fittings a) b) Step 1)--4) Reference drawing
(The picture is for reference only for the device)
a) --> a)1 --> a)2 --> a)STEP 1) b)2 foot S.S. flexable tube STEP 1)--4)
Y-type filter valve (need to be installed in front of the pump inlet) to replace
the 1/2" double female copper adapter assembly method:
1. First wrap the 1/2" head end screw of the attached 3/4"-to-1/2" (movable) s.s. adapter set with a white leak stop tape, and lock it into the Y-type filter valve with a wrench and universal fixing pliers. -The out (indicating arrow) is on the four inner teeth of the nozzle end. The Y valve filter barrel needs to face downwards to fully filter the liquid passing through in a free fall method.
2. Then wrap the original triangle valve removed from the wall or the newly purchased 1/2" triangle valve with a white stopper on the male teeth of the outlet end, and lock it into the Y-type filter valve with a wrench and universal fixing pliers. -Enter (indicating arrow tail) on the four-quarter inner teeth of the nozzle end.
3. Finally, wrap the white stop tape on the male teeth of the water inlet end of the triangle valve, and lock the whole set assembly together into the1/2" (female) inner teeth of the wall and turn it to the right (to provide a rotating space that can lock the components) , Take the 1/2" head end of the (movable) s.s. adapter set and add a black rubber backing ring Parking (locked to the INPUT address of the pump inlet).

  

24VDC Palm Pump
Home     Inquiry     e
-Mail Us    Bathtub

MEXA CO., LTD.  (Since 1979)
The Best ABS Engineering Plastic Wheel Cover's Manufacturer in Taiwan
P. O. Box: 30-534, Taipei 100, Taiwan, R. O. C.
Tel. +886-2-23657700 Fax.+886-2-23657702

Office: 3F., No. 128 Ku Ling Street, Taipei, Taiwan 100

Factory :No. 62 Kung Ming 2nd Road, Tsun Tou Liau Industry Area, Tainan, Taiwan Tel.06-2467820

www.autopure.com

Copyright© 2008 Jan.